Description
1. A wide variety of actuators are available for easy use.
2. High mechanical strength
. 3. Oil-resistant, waterproof, and dustproof construction.
Operation speed
0.5mm to 50cm /sAction frequency
Mechanical : 120 times / minuteElectrical : 30 times / minutelife
Mechanical : 10,000,000 timesElectrical : 500,000 timesImpact
Mechanical durability : Approximately 1000 m /s² ( approximately 100 G ‘s)Malfunction tolerance : Approximately 500 m /s² ( approximately 30 G ‘s)shock
10 to 55 Hz, 1.5 mm dual amplitudeContact resistance
25mΩ (mm) ( Initial )Insulation resistance
100MΩ and above ( under 500VDC )Withstand voltage
Between discontinuous terminals : 1000VAC, 50/60Hz, for 1 minute. Between current-carrying and no-current-carrying parts , and between terminals and ground : 1500VAC, 50/60Hz, for 1 minute.Ambient temperature
Operating temperature : -5 to +65 ℃Ambient humidity
Below 95%RHProtective Structure
IP65
TZ2
Operation speed
0.01mm to 1m/s (plunger type)Action frequency
Mechanical : 240 beats / minElectrical : 20 times / minutelife
Mechanical : 10,000,000 timesElectrical : 500,000 timesImpact
Mechanical durability : Approximately 1000 m /s² ( approximately 100 G ‘s)Malfunction tolerance : Approximately 300 m /s² ( approximately 30 G ‘s)shock
10 to 55 Hz, 1.5 mm dual amplitudeContact resistance
15m Ω (mm) ( Initial )Insulation resistance
100MΩ and above ( under 500VDC )Withstand voltage
Between discontinuous terminals : 1000VAC, 50/60Hz, for 1 minute. Between current-carrying and no-current-carrying parts , and between terminals and ground : 1500VAC, 50/60Hz, for 1 minute.Ambient temperature
Use at temperatures ranging from -10°C to +80°C (but must not freeze).Ambient humidity
Below 95%RHProtective Structure
IP67
TZ3
Operation speed
1mm to 1m/sAction frequency
Mechanical : 120 times / minuteElectrical : 30 times / minutelife
Mechanical : 10,000,000 timesElectrical : 500,000 timesImpact
Mechanical durability : Approximately 1000 m /s² ( approximately 100 G ‘s)Malfunction tolerance : Approximately 500 m /s² ( approximately 50 G ‘s)shock
10 to 55 Hz, 1.5 mm dual amplitudeContact resistance
25mΩ (mm) ( Initial )Insulation resistance
100MΩ and above ( under 500VDC )Withstand voltage
Between discontinuous terminals : 1000VAC, 50/60Hz, for 1 minute. Between current-carrying and no-current-carrying parts , and between terminals and ground : 1500VAC, 50/60Hz, for 1 minute.Ambient temperature
Operating temperature: -10 to +70℃Ambient humidity
Below 95%RHProtective Structure
IP67
TZ5
Operation speed
1mm to 2m/s (TZ5104 type)Action frequency
Mechanical : 120 times / minuteElectrical : 30 times / minutelife
Mechanical : 10,000,000 timesElectrical : 500,000 timesImpact
Mechanical durability : Approximately 1000 m /s² ( approximately 100 G ‘s)Malfunction tolerance : Approximately 300 m /s² ( approximately 50 G ‘s)shock
10 to 55 Hz, 1.5 mm dual amplitudeContact resistance
15m Ω (mm) ( Initial )Insulation resistance
100MΩ and above ( under 500VDC )Withstand voltage
Between discontinuous terminals : 1000VAC, 50/60Hz, for 1 minute. Between current-carrying and no-current-carrying parts , and between terminals and ground : 2200VAC, 50/60Hz, for 1 minute.Ambient temperature
Operating temperature: -10 to +80℃Ambient humidity
Below 95%RHProtective Structure
IP65
TZ6
Type
TZ-6001
TZ-6002
TZ-6003
TZ-6004
TZ-6043
TZ-6101
TZ-6102
TZ-6104
TZ-6104
TZ-6143OFmax
350g
350g
570g
570g
800g
500g
640g
640gRF minimum
114g
114g
170g
170g
240g
100g
230g
230gPT maximum
0.4mm
0.5mm
4mm
4mm
2mm
1mm
5mm
5mmOT minimum
5.5mm
3.6mm
6mm
6mm
5mm
3.5mm
6mm
6mmMD maximum
0.05mm
0.05mm
0.4mm
0.4mm
0.1mm
0.12mm
0.4mm
0.4mmOP
38.2
±0.8mm 49.7
±1mm – – 45.8
±0.8mm 49.7
±0.8mm – –
TZ7
Operation speed
0.01mm to 50cm/s (locking plunger type)Action frequency
Mechanical : 120 times / minuteElectrical : 120 times / minutelife
Mechanical : 10,000,000 timesElectrical : 500,000 timesImpact
Mechanical durability : Approximately 1000 m /s² ( approximately 100 G ‘s)Malfunction tolerance : Approximately 300 m /s² ( approximately 50 G ‘s)shock
10 to 55 Hz, 1.5 mm dual amplitudeContact resistance
15m Ω (mm) ( Initial )Insulation resistance
100MΩ and above ( under 500VDC )Withstand voltage
Between discontinuous terminals : 1000VAC, 50/60Hz, for 1 minute. Between current-carrying and no-current-carrying parts , and between terminals and ground : 1500VAC, 50/60Hz, for 1 minute.Ambient temperature
Operating temperature: -10 to +80℃Ambient humidity
Below 95%RHProtective Structure
IP65
TZ8
Operation speed
0.5mm to 50cm/sAction frequency
Mechanical : 120 times / minuteElectrical : 30 times / minutelife
Mechanical : 10,000,000 timesElectrical : 500,000 timesImpact
Mechanical durability : Approximately 1000 m /s² ( approximately 100 G ‘s)Malfunction tolerance : Approximately 500 m /s² ( approximately 50 G ‘s)shock
10 to 55 Hz, 1.5 mm dual amplitudeContact resistance
25mΩ (mm) ( Initial )Insulation resistance
100MΩ and above ( under 500VDC )Withstand voltage
Between discontinuous terminals : 1000VAC, 50/60Hz, for 1 minute. Between current-carrying and no-current-carrying parts , and between terminals and ground : 1500VAC, 50/60Hz, for 1 minute.Ambient temperature
Use at temperatures ranging from -5°C to +65°C.Ambient humidity
Below 95%RHProtective Structure
IP65
TZ9
Operation speed
0.5mm to 50cm/sAction frequency
Mechanical : 120 times / minuteElectrical : 30 times / minutelife
Mechanical: 10,000,000 cycles (under rated OT value)Electrical : 500,000 timesImpact
Mechanical durability : Approximately 1000 m /s² ( approximately 100 G ‘s)Malfunction tolerance : Approximately 300 m /s² ( approximately 30 G ‘s)shock
10 to 55 Hz, 1.5 mm dual amplitudeContact resistance
25mΩ (mm) ( Initial )Insulation resistance
100MΩ and above ( under 500VDC )Withstand voltage
Between discontinuous terminals : 1000VAC, 50/60Hz, for 1 minute. Between current-carrying and no-current-carrying parts , and between terminals and ground : 1500VAC, 50/60Hz, for 1 minute.Ambient temperature
Use at temperatures ranging from -5°C to +65°C.Ambient humidity
Below 95%RHProtective Structure
IP65
TZ93
Operation speed
0.1mm to 50cm/sAction frequency
Mechanical : 30 times / minuteElectrical : 30 times / minutelife
Mechanical: 1,000,000 cycles (at rated OT value)Electrical: 150,000 timesImpact
Mechanical durability : Approximately 1000 m /s² ( approximately 100 G ‘s)Malfunction tolerance : Approximately 300 m /s² ( approximately 30 G ‘s)shock
10 to 55 Hz, 1.5 mm dual amplitudeContact resistance
25mΩ (mm) ( Initial )Insulation resistance
100MΩ and above ( under 500VDC )Withstand voltage
AC2500V/Umip4KVAmbient temperature
Use at temperatures ranging from -30°C to +70°C.Ambient humidity
Below 95%RHProtective Structure
IP65
1. A wide variety of actuators are available for easy use.
2. High mechanical strength
. 3. Oil-resistant, waterproof, and dustproof construction.
Professional engineering support with 17 years of experience in automation and electrical components.
Stable and reliable production of PLCs, I/O modules, relays, terminals, and switches.
Quality-first processes ensuring consistent performance and customer trust.
Continuous improvement to support automation, new energy, and electrical industries.
Shenzhen Yulian Technology Co., Ltd. operates with a strong commitment to quality, safety, and environmental responsibility. Supported by modern production facilities and a professional engineering team, we follow standardized management systems to ensure product consistency, reliability, and customer satisfaction.
From manufacturing to final inspection, every process is carefully controlled to meet international standards and long-term performance requirements for automation and electrical components.

From standard automation products to customized electrical components – we deliver stable performance, consistent quality, and global-grade reliability for industrial and new energy applications.
Reviews
There are no reviews yet.