enterRTDResistance temperature detector (RTD) (Pt 100 Ω IEC751)VDC0 – 5 V dc ※ When using an electronic humidity sensor (e.g., EE99), connect a 250Ω resistor in parallel with an external resistor.Sampling period125 msMeasurement rangetemperature-100.0 ~ 200.0 °Chumidity0.0 ~ 100.0 % RHIndication accuracytemperature± 0.1% of FShumidity± 2% of FSContact input (D/I)8 o’clock (1a 8 o’clock, 2 COM)
power supply voltage100 – 240 V ac voltage variation rate ±10%Power frequency50 – 60 HzConsume electricity20 VA maxInsulation resistance500 V dc 20 MΩ and above power supply terminals – housing, input terminals – housingWithstand voltage2500 V ac 50 – 60 Hz
Power terminals – Housing (F/G), Input terminals – Housing (F/G), Input terminals – Power terminalsexternal power supply24 V dc 18 W max. (Input, Output Board)
+ Functional Specifications
enter
Enter Park JungTemperature: -100.00 ~ 100.00 °C
Humidity: -100.0 ~ 100.0 % RHDry and wet bulb sensors, Park JungAfter removing the gauze from the wet-bulb sensor, correct the deviation between the dry and wet-bulb sensors.ScalingDC voltage (V dc): Input scaling factor according to the conversion range.Input Filtering (LPF)2 ~ 180 (seconds)Input disconnection detectionUp Scale (when using RTD input)
Stop operation when the deviation exceeds ±5% of the range.Control ModeOperation method selectionSelectable fixed-value control/programmable controlControl outputTemperature control outputSSR / SCR (4 – 20 mA dc)Humidity control outputSSR / SCR (4 – 20 mA dc)Control ActionPattern100 Modes (1 mode/100 segments)SegmentMaximum 6,000 segmentsPID group16 zones (4 zones for temperature x 4 zones for humidity)Auto tuningSelf-tuning based on target setpointsProportional band
(Proportional band)0.00 ~ 100.00%
(0.00% ON/OFF control during setting)Points Time
(Integral time)0.0 ~ 6,000 seconds (setting to 0 seconds indicates OFF state)Differential time
(Derivative time)0.0 ~ 6,000 seconds (setting to 0 seconds indicates OFF state)ON/OFF controlSet the proportional band (PB) to 0.0.Forward/ReverseSelect forward/reverse action from the control output menu.ON/OFF width0.1 ~ 300 ℃Humidity refers to wet-bulb temperature or its conversion value.Transmission outputTemperature and humiditySelect from 4 – 20 mA dc indicated value (PV), set value (SV), and output value (MV).Scaling
(Scaling ratio)Automatic scaling of the set upper and lower limits (4-20 mA dc)Alarm settingsSet alarmSystem alarms: 4 points, 4 alarms per mode.Alarm types20 types of alarms including absolute upper and lower limits / deviation of upper and lower limitsAbsolute AlertTemperature: -100.0 ~ 200.0 °CHumidity: 0.0 ~ 100.0 % RHDeviation AlarmTemperature: -300.0 ~ 300.0 °CHumidity: 0.0 ~ 100.0 % RHLagTemperature: 0.0 ~ 300.0 °CHumidity: 0.0 ~ 100.0 % RHPower outage memoryPreserving mediaBuilt-in Flash and FRAMSave functionSave program information and settings; restore temperature and humidity settings and indicator values.
+ Screen Specifications
Image specificationsTFT LCD 5.6”resolution640 x RGB x 480Backlight lifespanLED backlight (approximately 40,000 hrs)Tactile4-Wire Resistive TouchLanguage usedKorean/English, English/Chinese (Simplified/Traditional), Korean/Chinese (Simplified/Traditional)
+ Action Environment
Applicable ambient temperature0 ~ 50 °CSuitable ambient humidity20 ~ 90 RH (but without condensation)Storage temperature-25 °C ~ 70 °CVibration resistance10 ~ 55 Hz, width 0.75 mm, 3 directions, 4 cycles, 5 minutes/cycleImpact resistance147 m/s², 3 directions, 3rd orderExternal dimensions183(W) x 144(H) x 94(D)CertificationweightApproximately 2.35 kg (in package)
Touchscreen color LCD screen – Precise control – 100 patterns (6,000 segments in total) – Independent PID control for temperature/humidity – Multiple alarm functions – 8 digital input (DI) contacts, 20 digital output (DO) contacts – Communication functions (RS232, RS422/485)
Professional engineering support with 17 years of experience in automation and electrical components.
Precision Manufacturing
Stable and reliable production of PLCs, I/O modules, relays, terminals, and switches.
Quality Assurance
Quality-first processes ensuring consistent performance and customer trust.
R&D Innovation
Continuous improvement to support automation, new energy, and electrical industries.
Our Certificates
Shenzhen Yulian Technology Co., Ltd. operates with a strong commitment to quality, safety, and environmental responsibility. Supported by modern production facilities and a professional engineering team, we follow standardized management systems to ensure product consistency, reliability, and customer satisfaction.
From manufacturing to final inspection, every process is carefully controlled to meet international standards and long-term performance requirements for automation and electrical components.
Need Reliable Automation & Electrical Component Solutions?
From standard automation products to customized electrical components – we deliver stable performance, consistent quality, and global-grade reliability for industrial and new energy applications.
Reviews
There are no reviews yet.