YULIAN

KXA Series

model KX2A KX3A KX4A KX7A KX9A KX4P

enter

Types of thermocouples K, J, E, T, R, B, S, L, N, U, W, PLIIReference contact point

Correction degree ±1.5 ºC (within 0 ~ 50ºC)Types of resistance thermometers JPT100, PT100Allowable line resistance The impedance between the three wires should be within 10Ω (but the impedance values ​​between the three wires must be the same).DC voltage 1 ~ 5 V, 0 ~ 10 VDisplay accuracy ±0.5% (See input table)Input disconnection detection Out of rangeSampling period 250 ms

Output

Relay output ▪ KX2A, KX3A, KX4A, KX7A, KX9A

NO: 5 A 250 VAC, 5 A 30 VDC (resistive load)

NC: 2 A 250 VAC, 1 A 30 VDC (resistive load), Switch life: 1 million cycles (no load)▪ KX4P

3 A 240 VAC, 3 A 30 VDC (resistive load), switch life: 1 million cycles (no load).Voltage output Turn-on voltage: 12 VDC or higher; turn-off voltage: 0.1 VDC or lower; load resistance: 600Ω or higher.Current output 4~20 mA, accuracy: ±0.2% of full scale ±1 digit, load resistance: below 600Ω

control

type On/Off, PID ControlOutput Action Reverse movement, forward movementOver-integral

Protective function Automatic (A=0), 0.1 ~ 100%

Options

alarm

Output

ALH

▪ KX2A, KX3A, KX9A

NO: 5 A 250 VAC, 5 A 30 VDC (resistive load)

NV: 2 A 250 VAC, 1 A 30 VDC (resistive load), Switching life: 1 million cycles (no load)▪ KX4A, KX7A, KX4P

3 A 240 VAC, 3 A 30 VDC (resistive load), switch life: 1 million cycles (no load).

ALL

3 A 240 VAC, 3 A 30 VDC (resistive load), switch life: 1 million cycles (no load).

LBA

▪ KX2A, KX3A, KX7A, KX9A

3 A 240 VAC, 3 A 30 VDC (resistive load), switch life: 1 million cycles (no load).Transmission output 4~20 mA, accuracy: ±0.2% of full scale ±1 digit, load resistance: below 600Ω

power supply

power supply voltage 100 – 240 VAC (±10 %), 50 – 60 Hz, 24 VDC (±10 %)AC power type

Power consumption Below 8.5 VA Below 7 VA Below 8.5 VA Below 9.0 VA Below 7 VADC power supply type

Power consumption Below 3.5 W Below 3.2 W Below 3.5 W Below 3.0 WInsulation resistance 20 MΩ and above (primary terminal – secondary terminal)Withstand voltage 3,000 VAC, 1 minute (1st terminal – 2nd terminal)

Installation Environment

Temperature and humidity 0 ~ 50 ºC, 35 ~ 85 % RH (but must not condense)environment Please refer to the safety precautions.Certification CE KCweight 170 g 110 g 170 g 240 g 110 g
Category:

Description

Fuzzy logic control, PID auto-tuning
– 3-zone PID/group PID (3 types)
– Ramp control function
– Heating/cooling control, HBA
– 3 setpoints selectable via contact input (DI)
– Communication functions (RS485/422)

 

download:KXA_user_en_251017

Reviews

There are no reviews yet.

Be the first to review “KXA Series”

Your email address will not be published. Required fields are marked *

Engineering Excellence

Professional engineering support with 17 years of experience in automation and electrical components.

Precision Manufacturing

Stable and reliable production of PLCs, I/O modules, relays, terminals, and switches.

Quality Assurance

Quality-first processes ensuring consistent performance and customer trust.

R&D Innovation

Continuous improvement to support automation, new energy, and electrical industries.

Our Certificates

Shenzhen Yulian Technology Co., Ltd. operates with a strong commitment to quality, safety, and environmental responsibility. Supported by modern production facilities and a professional engineering team, we follow standardized management systems to ensure product consistency, reliability, and customer satisfaction.

From manufacturing to final inspection, every process is carefully controlled to meet international standards and long-term performance requirements for automation and electrical components.

Need Reliable Automation & Electrical Component Solutions?

From standard automation products to customized electrical components – we deliver stable performance, consistent quality, and global-grade reliability for industrial and new energy applications.